Products · EnOcean Sensors

EnOcean Sensors

EnOcean sensors from DEUTA Controls transmit their readings wirelessly according to ISO/IEC 14543-3-10 and are powered by a solar cell, battery, power supply or PoE. All variants, including part numbers, device profiles, and radio certifications. The list is available as a CSV file with your current selection and as a complete Excel file for bulk calculations.

Complete list as Excel
Measured quantity
Energy Supply
Radio License
Device Profile
80 variants across 19 productsSorted by order number
NumberTypeProduct and DimensionsProfilePower SupplyApprovalBookmark
12286AL-431-00-868EnoSense® Wall+DeskVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellCE
12301AL-602-01-868EnoPuck® CO2CO2: 0–2,550 ppm · Temperature: 0 °C–50 °C · Humidity: 0–95% rel. hum.A5-09-04 +1External 12 V DC Power AdapterCE
12321AL-432-00-868EnoSense® PIR Ceiling · WhiteMotionA5-07-03 +4Solar CellCE
12330AL-602-02-868EnoPuck® CO2 NOISECarbon Dioxide and SoundA5-09-04 +3External 12 V DC power adapterCE
12391AL-435-00-868EnoSense® Temp/RH · whiteTemperature: 0 °C to 60 °C · Humidity: 0 to 95% rel. humidityA5-04-031 CR2032 batteryCE
12393AL-431-00-902EnoSense® Wall+Desk · 902 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellFCC
12394AL-432-00-902EnoSense® PIR Ceiling · white · 902 MHzMotionA5-07-03 +4Solar cellFCC
12432AL-436-00-868EnoSense® People CounterPeople CountingD1-07-102x AA, VARTA Industrial, includedCE
12433AL-602-02-868EnoPuck® CO2 WALLCO2: 0–2,550 ppm · Temperature: 0 °C–50 °C · Humidity: 0–95% rel. humidityA5-09-04 +1External 12 V DC Power AdapterCE
12452AL-436-00-868EnoSense® People Counter · BlackPeople CountingD1-07-102x AA, VARTA Industrial, includedCE
12465AL-436-00-868EnoSense® People Counter · whitePeople CountingD1-07-102 AA batteries, VARTA Industrial, includedCE
12466AL-436-00-902EnoSense® People Counter · 902 MHzPeople CountingD1-07-102 AA batteries, VARTA Industrial, includedFCC
12467AL-436-00-902EnoSense® People Counter · black · 902 MHzPeople CountingD1-07-102 AA batteries, VARTA Industrial, includedFCC
12468AL-436-00-902EnoSense® People Counter · white · 902 MHzPeople CountingD1-07-102 AA batteries, VARTA Industrial, includedFCC
12470AL-431-00-868EnoSense® Wall+Desk · whiteVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellCE
12471AL-431-00-868EnoSense® Wall+Desk · blackVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellCE
12472AL-431-00-902EnoSense® Wall+Desk · white · 902 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellFCC
12473AL-431-00-902EnoSense® Wall+Desk · black · 902 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellFCC
12515AL-431-00-921EnoSense® Wall+Desk · white · 921 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellNCC
12517AL-432-02-928EnoSense® PIR Ceiling · White · 928 MHzMotionA5-07-03 +4Solar cellNCC
12518AL-436-00-921EnoSense® People Counter · white · 921 MHzPeople CountingD1-07-102 AA batteries, VARTA Industrial, includedNCC
12523AL-431-00-921EnoSense® Wall+Desk · white · 921 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellKC
12524AL-431-00-868EnoSense® Wall+Desk · whiteVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellCCC
12533AL-432-00-921EnoSense® PIR Ceiling · white · 921 MHzMotionA5-07-03 +4Solar cellKC
12534AL-432-00-868EnoSense® PIR Ceiling · WhiteMotionA5-07-03 +4Solar cellCCC
12537AL-436-00-921EnoSense® People Counter · white · 921 MHzPeople CountingD1-07-102 AA batteries, VARTA Industrial, includedKC
12538AL-436-00-868EnoSense® People Counter · whitePeople CountingD1-07-102 AA batteries, VARTA Industrial, includedCCC
12562AL-602-01-902EnoPuck® CO2 · 902 MHzCO2: 0–2,550 ppm · Temperature: 0 °C–50 °C · Humidity: 0–95% rel. humidityA5-09-04 +1External 12 V DC Power AdapterFCC
12563AL-602-02-902EnoPuck® CO2 NOISE · 902 MHzCarbon Dioxide and SoundA5-09-04 +3External 12 V DC Power AdapterFCC
12564AL-602-02-902EnoPuck® CO2 WALL · 902 MHzCO2: 0–2,550 ppm · Temperature: 0 °C–50 °C · Humidity: 0–95% relative humidityA5-09-04 +1External 12 V DC Power AdapterFCC
12588AL-437-03-868EnoSense® Desk · whiteVibration / Acceleration: ± 2 gA5-07-011 CR2032 batteryCE
12590AL-439-00-868EnoSense® CO2 · whiteCO2: 0–10,000 ppm · Temperature: 0 °C–+80 °C · Humidity: 0–95% rel. humidityA5-09-04 +2Solar cell, front sideCE
12598AL-431-00-928EnoSense® Wall+Desk · 928 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellCRC
12603AL-431-00-928EnoSense® Wall+Desk · 928 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellARIB
12604AL-436-00-928EnoSense® People Counter · white · 928 MHzPeople CountingD1-07-102 AA batteries, VARTA Industrial, includedARIB
12607AL-432-02-928EnoSense® PIR Ceiling · white · 928 MHzMotionA5-07-03 +4Solar cellARIB
12619AL-439-00-868EnoSense® CO2 · blackCO2: 0 to 10,000 ppm · Temperature: 0 °C to +80 °C · Humidity: 0 to 95% rel. humidityA5-09-04 +2Solar cell, front sideCE
12620AL-440-00-868EnoSense® NOISE · whiteSoundD1-07-11Solar cell, front-sideCE
12621AL-440-00-868EnoSense® NOISE · blackSoundD1-07-11Solar cell, front-facingCE
12623AL-437-03-902EnoSense® Desk · white · 902 MHzVibration / Acceleration: ± 2 gA5-07-011 CR2032 batteryFCC
12635AL-431-00-928EnoSense® Wall+Desk · black · 928 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellARIB
12636AL-431-00-928EnoSense® Wall+Desk · white · 928 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellARIB
12637AL-440-00-902EnoSense® NOISE · white · 902 MHzSoundD1-07-11Solar cell, front sideFCC
12638AL-440-00-902EnoSense® NOISE · white · 902 MHzSoundD1-07-11Solar cell, front sideFCC
12639AL-439-00-902EnoSense® CO2 · white · 902 MHzCO2: 0–10,000 ppm · Temperature: 0 °C–+80 °C · Humidity: 0–95% rel. humidityA5-09-04 +2Solar cell, front sideFCC
12640AL-439-00-902EnoSense® CO2 · white · 902 MHzCO2: 0 .. 10,000 ppm · Temperature: 0 °C .. +80 °C · Humidity: 0 .. 95% rel. hum.A5-09-04 +2Solar cell, front sideFCC
12643AL-431-00-928EnoSense® Wall+Desk · black · 928 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellCRC
12672AL-602-04-921EnoPuck® CO2 WALL · 921 MHzCO2: 0 – 2,550 ppm · Temperature: 0 °C – 50 °C · Humidity: 0 – 95% rel. humidityA5-09-04 +1External 12 V DC power adapterNCC
12679AL-602-04-921EnoPuck® CO2 WALL · 921 MHzCO2: 0–2,550 ppm · Temperature: 0 °C–50 °C · Humidity: 0–95% rel. humidityA5-09-04 +1External 12 V DC Power AdapterKC
12759AL-436-00-928EnoSense® People Counter · black · 928 MHzPeople CountingD1-07-102 AA batteries, VARTA Industrial, includedARIB
12760AL-436-00-928EnoSense® People Counter · 928 MHzPeople CountingD1-07-102 AA batteries, VARTA Industrial, includedARIB
12762AL-431-00-928EnoSense® Wall+Desk · white · 928 MHzVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellCRC
12776AL-602-01-921EnoPuck® CO2 · 921 MHzCO2: 0 .. 2,550 ppm · Temperature: 0 °C .. 50 °C · Humidity: 0 .. 95% rel. humidityA5-09-04 +1External 12 V DC Power AdapterNCC
12782AL-602-01-921EnoPuck® CO2 · 921 MHzCO2: 0–2,550 ppm · Temperature: 0 °C–50 °C · Humidity: 0–95% rel. humidityA5-09-04 +1External 12 V DC Power AdapterKC
12790AL-431-00-868EnoSense® Wall+Desk · whiteVibration / Acceleration: ± 2 gA5-14-05 +8Solar cellIMDA
12791AL-436-00-868EnoSense® People Counter · white · 921 MHzPeople CountingD1-07-102 AA batteries, VARTA Industrial, includedIMDA
12792AL-602-01-868EnoPuck® CO2CO2: 0–2,550 ppm · Temperature: 0 °C–50 °C · Humidity: 0–95% rel. humidityA5-09-04 +1External 12 V DC Power AdapterIMDA
12795AL-432-00-868EnoSense® PIR Ceiling · whiteMotionA5-07-03 +4Solar cellIMDA
12829AL-435-00-902EnoSense® Temp/RH · white · 902 MHzTemperature: 0 °C to 60 °C · Humidity: 0 to 95% rel. humidityA5-04-031 CR2032 batteryFCC
12836AL-443-00-868EnoSense® LUX · whiteBrightness: 1 lx – 60,000 lxA5-06-01 +11 CR2032 batteryCE
12837AL-443-00-902EnoSense® LUX · white · 902 MHzIlluminance: 1 lx to 60,000 lxA5-06-01 +11 CR2032 batteryFCC
12841AL-444-00-868EnoSense® Window · whiteWindowD5-00-01 +21 CR2032 batteryCE
12842AL-444-00-902EnoSense® Window · white · 902 MHzWindowD5-00-01 +21 CR2032 batteryFCC
12846AL-437-02-868EnoSense® Desk VIB · whiteVibration / Acceleration: ± 2 gA5-07-011 CR2032 batteryCE
12847AL-437-02-902EnoSense® Desk VIB · white · 902 MHzVibration / Acceleration: ± 2 gA5-07-011 CR2032 batteryFCC
12850AL-439-00-921EnoSense® CO2 · white · 921 MHzCO2: 0–10,000 ppm · Temperature: 0 °C–+80 °C · Humidity: 0–95% rel. humidityA5-09-04 +2Solar cell, front sideNCC
12852AL-439-00-921EnoSense® CO2 · black · 921 MHzCO2: 0–10,000 ppm · Temperature: 0 °C–+80 °C · Humidity: 0–95% rel. humidityA5-09-04 +2Solar cell, front sideKC
12853AL-460-00-868EnoSense® Presence Count · whitePresenceMSCPower over Ethernet (PoE)CE
12862AL-438-00-868EnoSense® PIR DOT · whiteBrightness: 1 lx – 60,000 lxA5-07-03 +21 CR3032 batteryCE
12867AL-438-00-902EnoSense® PIR DOT · white · 902 MHzBrightness: 1 lx to 60,000 lxA5-07-03 +21 CR3032 batteryFCC
12874AL-460-00-902EnoSense® Presence Count · white · 902 MHzPresenceMSCPower over Ethernet (PoE)FCC
12877AL-439-00-921EnoSense® CO2 · white · 921 MHzCO2: 0–10,000 ppm · Temperature: 0 °C–+80 °C · Humidity: 0–95% rel. hum.A5-09-04 +2Solar cell, front sideKC
12900AL-439-00-921EnoSense® CO2 · black · 921 MHzCO2: 0–10,000 ppm · Temperature: 0 °C–+80 °C · Humidity: 0–95% rel. hum.A5-09-04 +2Solar cell, front sideNCC
12904AL-446-00-868EnoSense® RADONRadon: 0 .. 3,696 Bq/m³ · plus device status (temperature/humidity inside the housing)A5-12-00 +1Power over Ethernet (PoE)CE
12906AL-461-00-868EnoSense® People Counter PRO · whitePeople countingMSCPoE / USB / 12 .. 48 V DCCE
12939AL-447-00-868EnoSense® PM VOCPM1.0 / PM2.5: 0 to 1,000 µg/m³ · PM4 / PM10: 0 to 1,000 µg/m³ · VOC Index: VOC Index 1 to 500D1-09-08External plug-in power supply, 12 V DC (included)CE
12943AL-448-31-868EnoSense® 3PH Current SenseCurrent: 1 A ... 80/200/600 AD2-32-02Energy Harvesting mittels der aufklappbaren CE
12965AL-448-32-868EnoSense® 3PH Current SenseCurrent: 1 A to 80/200/600 AD2-32-02Energy Harvesting mittels der aufklappbaren CE
12966AL-448-33-868EnoSense® 3PH Current SenseCurrent: 1 A ... 80/200/600 AD2-32-02Energy Harvesting mittels der aufklappbaren CE
12967AL-447-00-902EnoSense® PM VOC · 902 MHzPM1.0 / PM2.5: 0 .. 1,000 µg/m³ · PM4 / PM10: 0 .. 1,000 µg/m³ · VOC Index: VOC Index 1 .. 500D1-09-08External plug-in power supply, 12 V DC (includedFCC
How Devices Are Added to the System
Measure
Radio Link
Receive
Evaluate
Transmit