Technical data

Part No.12943
TypeAL-448-31-868
Device Profile (EEP)D2-32-02
Measurement RangeCurrent (3-phase): approx. 2 .. 80/200/600 A (depending on the model), 0 .. 80/200/600 A with internal batteries
Power SupplyEnergy Harvesting Using Split-Core Current Transformers
ApprovalsCE
OriginDeveloped and manufactured in Germany
Wireless InterfaceEnOcean
EU: 868.3 MHz
Additional InterfacesService button
SensorsCurrent transformers, hinged current transformers, depending on the model: 80 / 200 / 600 A
Environmental ConditionsOperating temperature: -5 °C to +50 °C
Storage temperature: -15 °C to +60 °C
Humidity: 0 to 80%
(non-condensing)
Protection class: IP20
Dimensions and WeightLength x Width x Height: approx. 80 x 35 x 20 mm
Weight: 50 g (without CT clamps)
AccessoriesFold-out current transformers (3x), included

Description

Measurement of currents in three-phase systems for monitoring and analysis applications.

The EnoSense® 3PH Current Sense enables continuous measurement of current values in three-phase installations. Die Messung erfolgt ohne Eingriff in bestehende Systeme und eignet sich insbesondere für die Nachrüstung in Bestandsanlagen.

The collected data forms the basis for energy monitoring, load analysis, and condition-based evaluation.

The EnoSense® 3PH Current Sense continuously provides precise measurements from the three current sensors.

Energy consumption is decentralized - but transparency is often lacking at the level of individual circuits or systems.

With the EnoSense® 3PH Current Sense you create the basis for:

The sensor measures the currents of all three phases via external current transformers (clip-on design). Installation is performed without interrupting the conductors or interfering with the existing infrastructure.

The 3PH Current Sense is specially designed for use in existing and new buildings:

Subdistribution Panels: Recording Individual Outputs Without Additional Measurement Hardware in the Control Cabinet

HVAC and Building Services Engineering: Analysis of Ventilation Systems, Pumps, and Cooling and Heating Systems

Variants and Part Numbers

3 Versions
Part No.TypeRadio FrequencyDesignApprovalMarketBookmark
12943AL-448-31-868868.3 MHz—CEEurope
12965AL-448-32-868868.3 MHz—CEEurope
12966AL-448-33-868868.3 MHz—CEEurope

CE/RED applies to all devices. Additional radio approvals depend on the model: Please select the part number for your target market. Other frequencies are available upon request.

For planning

Documents

Everything you need to know about EnoSense® 3PH Current Sense for bidding and planning—no registration required.

Data SheetTechnical Specifications as a PDF; opens in your browser.
EEP ProfileEEP D2-32-02, EnOcean Alliance Profile.
ConformityCE/RED for all devices. Documentation is provided on a market-by-market basis; the variant's part number is the determining factor. All documents in the Download Center →