EnoSense® RADON
The EnoSense® RADON, featuring measurement technology from the global market leader Ecosense, is a professional EnOcean radon sensor designed for businesses, government agencies, and public buildings, and was specifically developed for use in occupational safety and professional building management.

Radon Explained in Two Minutes
Explanatory Video · 2 MinutesExplanatory video featuring Enno, 1:56 · Voiceover and music generated by AI · All measurements shown in the video are examples
Invisible, odorless, radioactive—and perhaps right in your own building. Enno, our mascot for building sensor technology, explains how radon enters the home, why an annual measurement doesn’t show the peaks, and what the EnoSense® RADON makes visible:
- How radon is formed and enters a building through cracks, joints, and pipe penetrations.
- Why a dosimeter provides only an average reading after several months and hides the peaks.
- What continuous measurement every 10 minutes reveals: daily fluctuations, weekends, and ventilation.
- The reference value of 300 Bq/m³ also applies to workplaces.
Legally required radon measurements are conducted by agencies recognized by the BfS. The EnoSense® RADON shows what is happening inside the building in the meantime.
Technical data
| Order Number | 12904 |
| Item Number | AL-446-00-868 |
| Device Profile (EEP) | A5-12-00, A5-04-03 |
| Measurement Range | Radon: 7.4 to 3,696 Bq/m³ |
| Device Status | Temperature 0–60 °C and relative humidity 0–95% inside the enclosure—for status monitoring; not suitable as room climate values |
| Power Supply | Power Over Ethernet (PoE) / 12–48 V DC |
| Approvals | CE |
| Origin | Developed and manufactured in Germany |
| Wireless Interface | EnOcean EU: 868.3 MHz |
| Additional Interfaces | Service LEDs: 1 x RGB ; Service button |
| Sensors | Radon: Pulse ionization chamber Device status: Temperature and humidity inside the housing |
| Environmental Conditions | Operating temperature: +10 °C to +50 °C Storage temperature: -15 °C to +60 °C Humidity: 0 to 80% (non-condensing) Protection class: IP20 |
| Dimensions and Weight | Length x Width x Height: 100 x 86 x 60 mm Weight: 270 g |
| Accessories | Screw-on mounting with wall bracket |
Description
The EnoSense® RADON, featuring measurement technology from the global market leader Ecosense, is a professional EnOcean radon sensor designed for businesses, government agencies, and public buildings, and was specifically developed for use in occupational safety and professional building management. It enables continuous indoor radon monitoring and helps operators detect radon exposure at an early stage and implement appropriate measures in the context of occupational safety and building operations.
In contrast to simple radon measuring devices for private use, EnoSense® RADON is consistently designed for long-term B2B use - reliable, low-maintenance and suitable for professional building operation.
The EnoSense® RADON continuously provides precise measurements of radon concentration. It also transmits temperature and relative humidity readings from inside the housing. These device readings are used to monitor the sensor’s condition; due to the internal heat generated by the measurement chamber, they are not suitable as room climate readings. For room temperature and humidity, we recommend using a separate room sensor, such as the EnoSense® CO2 or EnoSense® Temp/RH.
Radon is a naturally occurring, radioactive noble gas that escapes from the ground. Es ist unsichtbar, geruchlos und geschmacklos – und kann nur durch eine Radonmessung festgestellt werden. Gerade in öffentlichen Gebäuden, in denen viele Menschen täglich Zeit verbringen, ist das Thema besonders wichtig.
In action at the University of La Laguna
In Action · European Cycling Day 2026About 140 EnoSense® RADON sensors are continuously monitoring the campus of the Universidad de La Laguna on Tenerife via the existing Wi-Fi network. The university presented its findings at the 2026 EnOcean Alliance Summit; here are the highlights in 45 seconds:
- Radon levels can fluctuate by up to ×10 in a single day. A single reading per room does not indicate when the radon level is high.
- On the Anchieta Campus, 1 out of 5 rooms exceeds the EU reference value of 300 Bq/m³.
- Side by side with a calibrated reference: correlation r = 0.96.
- In the lecture hall: With pressurized supply air operating at only 30% capacity, the level drops from 1,044 to 70 Bq/m³ during lectures.
The official assessment is based on the passive detector. The sensor network shows where and when action is needed.
Animation without sound, 45 seconds · Source: Universidad de La Laguna
Documents
Everything you need to know about EnoSense® RADON for bidding and planning—no registration required.
Related items from the planning phase
4 postsSimilar Products
Same function, different design or power supply
Carbon DioxideEnoPuck® CO2The “EnoPuck CO2” CO2 indicator can be used both as a standalone solution and in combination with …
Carbon Dioxide and SoundEnoPuck® CO2 NOISEIn addition to the features of the AL-602-01-868 EnoPuck CO2 traffic light, the EnoPuck CO2 NOISE offers …
Carbon DioxideEnoPuck® CO2 WALLEnoPuck CO2 WALL: The “EnoPuck CO2” CO2 indicator light was initially designed specifically for in-wall installation …
Particulate Matter and VOCsEnoSense® PM VOCThe EnoSense® PM VOC is a professional air quality sensor for businesses, government agencies, and public …Every sensor requires a receiver and a gateway: EnoDisc® and VL-700 BASE. Here’s how the system works together.