Radon-Prone Areas in Germany
Six federal states have designated areas where excessively high radon levels in buildings are particularly likely. In these areas, workplaces located on the ground floor or in basements are required to conduct measurements. Here you’ll find a list of all municipalities, the requirements, and the deadlines.
What Is a Radon-Prone Area?
Section 121 of the Radiation Protection ActThe states issue general orders designating the areas in which, in a significant number of buildings containing living spaces or workplaces, the annual average radon concentration is expected to exceed the reference value of 300 becquerels per cubic meter.
According to the Radiation Protection Ordinance, “a significant number” means that, across at least 75 percent of an area’s total area, the reference value is exceeded in at least 10 percent of the buildings. These areas are defined along administrative boundaries; in practice, this is done on a municipality-by-municipality basis. The basis for this includes, among other things, geological data and measurements of radon concentration in soil air.
These provisions have been in effect since the end of 2020 or 2021, respectively, and must be reviewed at least every ten years. Only the official announcement by the respective state is legally binding; the overview provided by the Federal Office for Radiation Protection (BfS) and this list are for informational purposes only.
Who Must Take Measurements
§ 127 Radiation Protection ActThe results must be recorded and communicated immediately to the affected employees and to the works council or staff council.
Measurement, Actions, Registration
The Process in Five Steps| Step | What to Do | Deadline | Basis |
|---|---|---|---|
| 1 Measurements | Measurements taken over a total of twelve months at representative measurement sites. The measuring instruments are provided by a BfS-accredited organization and are generally analyzed there. | 18 months | § 127 StrlSchG, § 155 StrlSchV |
| 2. Action | If the annual average exceeds 300 Bq/m³, measures must be taken to reduce the level, such as ventilation, sealing, or extraction. | Immediately | Section 128(1) of the Radiation Protection Act (StrlSchG) |
| 3 Check | Verify the success of the measures by taking another measurement and recording the result. | 30 months from the date of discovery | § 128(2) StrlSchG |
| 4 Registration | If the value is still above the reference value after that, the workplace must be registered with the competent authority. | without delay | § 129 StrlSchG |
| 5. Estimate | Assessment of workers’ exposure. If the effective dose may exceed 6 millisieverts per year, the rules for occupational radiation protection apply. | 6 months after registration | Sections 130, 131 of the Radiation Protection Act (StrlSchG) |
New Construction in the Precautionary Zone
§ 123 StrlSchG, § 154 StrlSchVAnyone constructing a building with living spaces or workplaces must prevent or significantly impede the ingress of radon from the building site. Outside of radon prevention zones, this obligation is deemed fulfilled by implementing moisture protection measures in accordance with recognized technical standards. In radon prevention zones, this obligation is considered fulfilled if at least one additional measure is implemented, such as an extraction system under the foundation slab or at perimeter joints, targeted manipulation of pressure conditions, or the use of radon-tight materials. Radon protection should also be taken into account in renovations that significantly reduce air exchange, such as those involving new windows.
All Radon Precaution Areas by State
Status of designations: June 15, 2021Compiled from the BfS overview, which is based on the announcements by the federal states. In Bavaria, some entries refer to unincorporated areas. The official announcement by the respective federal state is binding; links to these announcements are provided under each federal state.
Baden-Württemberg · Bavaria · Lower Saxony · Saxony · Saxony-Anhalt · Thuringia
Baden-Württemberg · 29 entries
State Announcement →| County | Municipalities |
|---|---|
| Breisgau-High Black Forest | Bollschweil, Horben, Münstertal, Oberried, Schluchsee |
| Lörrach | Aitern, Böllen, Fröhnd, Häg-Ehrsberg, Kleines Wiesental, Schönau im Schwarzwald, Schönenberg, Todtnau, Tunau, Utzenfeld, Wembach, Wieden, Zell im Wiesental |
| Ortenau District | Gutach (Black Forest Railway) |
| Rottweil | Lauterbach, Schiltach |
| Schwarzwald-Baar District | Schonach |
| Waldshut | Dachsberg, Häusern, Herrischried, Ibach, Rickenbach, Sankt Blasien, Todtmoos |
Bavaria · 26 entries
State Announcement →| County | Municipalities |
|---|---|
| Wunsiedel in the Fichtelgebirge | Arzberg, Bad Alexandersbad, Höchstädt in the Fichtelgebirge, Hohenberg on the Eger, Kaiserhammer Forest-East, Kirchenlamitz, Marktleuthen, Marktredwitz, Martinlamitzer Forest-South, Meierhöfer Side, Nagel, Neubauer Forest-South, Röslau, Schirnding, Schönwald, Selb, Thiersheim, Thierstein, Tröstau, Tröstauer Forest-East, Tröstauer Forest-West, Vordorfer Forest, Weißenstadt, Weißenstadt Forest-North, Weißenstadt Forest-South, Wunsiedel |
Lower Saxony · 3 entries
State Announcement →| County | Municipalities |
|---|---|
| Goslar | Goslar, Clausthal-Zellerfeld, Braunlage |
Saxony · 107 entries
State Announcement →| County | Municipalities |
|---|---|
| Erzgebirge District | Amtsberg, Annaberg-Buchholz, Aue-Bad Schlema, Auerbach, Bärenstein, Bockau, Börnichen/Erzgeb., Breitenbrunn/Erzgeb., Burkhardtsdorf, Crottendorf, Deutschneudorf, Drebach, Ehrenfriedersdorf, Eibenstock, Elterlein, Gelenau/Erzgeb., Geyer, Gornau/Erzgeb., Großolbersdorf, Großrückerswalde, Grünhain-Beierfeld, Grünhainichen, Heidersdorf, Johanngeorgenstadt, Jöhstadt, Königswalde, Lauter-Bernsbach, Marienberg, Mildenau, Oberwiesenthal, Olbernhau, Pockau-Lengefeld, Raschau-Markersbach, Scheibenberg, Schlettau, Schneeberg, Schönheide, Schwarzenberg/Erzgeb., Sehmatal, Seiffen/Erzgeb., Stollberg/Erzgeb., Stützengrün, Tannenberg, Thalheim/Erzgeb., Thermalbad Wiesenbad, Thum, Wolkenstein, Zschopau, Zschorlau |
| Central Saxony | Augustusburg, Bobritzsch-Hilbersdorf, Brand-Erbisdorf, Dorfchemnitz, Eppendorf, Flöha, Frauenstein, Freiberg, Großhartmannsdorf, Halsbrücke, Leubsdorf, Lichtenberg/Erzgeb., Mulda/Sa., Neuhausen/Erzgeb., Oberschöna, Oederan, Rechenberg-Bienenmühle, Sayda, Weißenborn/Erzgeb. |
| Saxon Switzerland–Eastern Ore Mountains | Altenberg, Bad Gottleuba-Berggießhübel, Dippoldiswalde, Dorfhain, Freital, Glashütte, Hartmannsdorf-Reichenau, Hermsdorf (Erzgebirge), Klingenberg, Kreischa, Liebstadt, Tharandt |
| Vogtland District | Adorf/Vogtl., Auerbach/Vogtl., Bad Brambach, Bad Elster, Bergen, Eichigt, Ellefeld, Falkenstein/Vogtl., Grünbach, Klingenthal, Lengenfeld, Markneukirchen, Mühlental, Muldenhammer, Neustadt/Vogtl., Rodewisch, Schöneck/Vogtl., Steinberg, Theuma, Treuen, Werda |
| Zwickau | Crinitzberg, Hartmannsdorf near Kirchberg, Hirschfeld, Kirchberg, Langenweißbach, Wilkau-Haßlau |
Saxony-Anhalt · 15 entries
State Announcement →| County | Municipalities |
|---|---|
| Harz | Falkenstein/Harz, Harzgerode, Ilsenburg (Harz), Oberharz am Brocken, Thale, Wernigerode |
| Mansfeld-Südharz | Allstedt, Arnstein, Hettstedt, Lutherstadt Eisleben, Mansfeld, Sangerhausen, Südharz, Goldene Aue, Mansfelder Grund-Helbra |
Thuringia · 19 entries
State Announcement →| County | Municipalities |
|---|---|
| Altenburg Region | Posterstein |
| Gotha | Luisenthal, Tambach-Dietharz/Thuringian Forest |
| Greiz | Kauern, Korbußen, Paitzdorf, Ronneburg |
| Hildburghausen | Masserberg, Schleusegrund |
| Ilm District | Elgersburg, Großbreitenbach, Ilmenau |
| Saalfeld-Rudolstadt | Gräfenthal, Katzhütte, Schwarzatal |
| Schmalkalden-Meiningen | Floh-Seligenthal, Oberhof |
| Sonneberg | Goldisthal |
| Wartburg District | Ruhla |
When Continuous Monitoring Helps
Between Mandatory MeasurementsThe legally required measurement provides an annual average after twelve months. It does not reveal whether ventilation or sealing is effective until the next mandatory measurement—up to 30 months later.
For the mandatory measurement, only devices from a BfS-approved agency are accepted, including both passive detectors and electronic measuring devices. A separate continuous monitoring system does not replace these mandatory measurements, but it does show in real time when levels are rising and whether a measure is effective, and can control ventilation via the building automation system. The EnoSense® RADON transmits a measurement value via radio every 10 minutes for this purpose.
Continuous Monitoring in the Field
From the Field · European Radon Day 2026The University of La Laguna on Tenerife demonstrates how continuous monitoring can help in decision-making. It presented its findings at the 2026 EnOcean Alliance Summit; here are the key takeaways in 45 seconds:
- Radon levels can fluctuate by up to a factor of 10 in a single day. A single measurement per room does not indicate when exposure levels are high.
- On the Anchieta Campus, 1 out of 5 rooms exceeds the EU reference value of 300 Bq/m³.
- Side by side with a calibrated reference: correlation r = 0.96.
- In the lecture hall: With positive-pressure supply air running at just 30% capacity, the level drops from 1,044 to 70 Bq/m³ during lectures.
The official assessment relies on the passive detector. The sensor network indicates where and when action is needed.
Animation without sound, 45 seconds · Source: Universidad de La Laguna
Frequently Asked Questions
5 QuestionsHow can I find out if a location is in a radon-prone area?
Search for the municipality in the list on this page or on the map provided by the Federal Office for Radiation Protection. The state’s official announcement is binding; if in doubt, contact the state authority for information.
Do you have to measure radon levels outside a radon precautionary area?
Only at workplaces in certain sectors, such as water treatment plants, mines, or radon spas, or if the authority requires it. However, elevated levels can also occur outside these areas; a voluntary measurement provides clarity.
Does the testing requirement also apply to offices on upper floors?
In radon-risk areas, the requirement applies to workplaces on the ground floor and in basements. For upper floors, it applies only if the work area falls under this requirement or if the authorities mandate it.
What happens if the reference value is exceeded?
Measures to reduce radon levels must be taken immediately, and their effectiveness must be verified by a measurement within 30 months. If the level remains above the threshold, the workplace must be reported to the authorities and the exposure assessed.
When are radon prevention zones reviewed?
The Radiation Protection Act requires a review at least every ten years. Most of these provisions have been in effect since late 2020 or mid-2021.
New planning aids by email
New devices, firmware and software releases, application examples and planning aids – roughly every two months, at most once a month.
Subscribe to the newsletterInformation current as of October 3, 2026. Sources: Radiation Protection Act, Sections 121 through 131 and Annex 8; Radiation Protection Ordinance, Sections 153 through 155; Federal Office for Radiation Protection, Overview of Radon Precautionary Areas (as of June 15, 2021); announcements by the federal states. This information has been compiled to the best of our knowledge and does not constitute legal advice; the text of the current version and the announcements by the federal states are authoritative.
Are you conducting measurements in a radon-prone area?
Please provide us with the location, the rooms in question, and the target system. You’ll receive a recommendation for continuous monitoring, a list of order numbers, and a quote.