Planning Information · Radon

Radon-Prone Areas in Germany

Six federal states have designated areas where excessively high radon levels in buildings are particularly likely. In these areas, workplaces located on the ground floor or in basements are required to conduct measurements. Here you’ll find a list of all municipalities, the requirements, and the deadlines.

6Federal States with Radon Prevention Zones
199Municipalities and unincorporated areas
300 Bq/m³Annual average reference value
18 monthsTimeframe for measurement

What Is a Radon-Prone Area?

Section 121 of the Radiation Protection Act

The states issue general orders designating the areas in which, in a significant number of buildings containing living spaces or workplaces, the annual average radon concentration is expected to exceed the reference value of 300 becquerels per cubic meter.

According to the Radiation Protection Ordinance, “a significant number” means that, across at least 75 percent of an area’s total area, the reference value is exceeded in at least 10 percent of the buildings. These areas are defined along administrative boundaries; in practice, this is done on a municipality-by-municipality basis. The basis for this includes, among other things, geological data and measurements of radon concentration in soil air.

These provisions have been in effect since the end of 2020 or 2021, respectively, and must be reviewed at least every ten years. Only the official announcement by the respective state is legally binding; the overview provided by the Federal Office for Radiation Protection (BfS) and this list are for informational purposes only.

Who Must Take Measurements

§ 127 Radiation Protection Act
In the precautionary zoneWorkplaces on the ground floor or in the basementAnyone responsible for a workstation located indoors must have it tested if the workstation is on the ground floor or in the basement of a building in a radon prevention area.
EverywhereSpecific Work AreasRegardless of the area: underground mines, shafts, and caves—including visitor mines, radon spas and tunnels—as well as facilities for water extraction, treatment, and distribution.
Deadline18 monthsThe measurement must be completed within 18 months—after the area has been designated and work has commenced at the workplace. The authority may extend the deadline by no more than six months.
AgainAfter ChangesIf a change is made at the workplace that could cause the radon concentration to exceed the reference value, measurements must be taken again. The authority may also order measurements for other workplaces.

The results must be recorded and communicated immediately to the affected employees and to the works council or staff council.

Measurement, Actions, Registration

The Process in Five Steps
StepWhat to DoDeadlineBasis
1 MeasurementsMeasurements taken over a total of twelve months at representative measurement sites. The measuring instruments are provided by a BfS-accredited organization and are generally analyzed there.18 months§ 127 StrlSchG, § 155 StrlSchV
2. ActionIf the annual average exceeds 300 Bq/m³, measures must be taken to reduce the level, such as ventilation, sealing, or extraction.ImmediatelySection 128(1) of the Radiation Protection Act (StrlSchG)
3 CheckVerify the success of the measures by taking another measurement and recording the result.30 months from the date of discovery§ 128(2) StrlSchG
4 RegistrationIf the value is still above the reference value after that, the workplace must be registered with the competent authority.without delay§ 129 StrlSchG
5. EstimateAssessment of workers’ exposure. If the effective dose may exceed 6 millisieverts per year, the rules for occupational radiation protection apply.6 months after registrationSections 130, 131 of the Radiation Protection Act (StrlSchG)

New Construction in the Precautionary Zone

§ 123 StrlSchG, § 154 StrlSchV

Anyone constructing a building with living spaces or workplaces must prevent or significantly impede the ingress of radon from the building site. Outside of radon prevention zones, this obligation is deemed fulfilled by implementing moisture protection measures in accordance with recognized technical standards. In radon prevention zones, this obligation is considered fulfilled if at least one additional measure is implemented, such as an extraction system under the foundation slab or at perimeter joints, targeted manipulation of pressure conditions, or the use of radon-tight materials. Radon protection should also be taken into account in renovations that significantly reduce air exchange, such as those involving new windows.

All Radon Precaution Areas by State

Status of designations: June 15, 2021

Compiled from the BfS overview, which is based on the announcements by the federal states. In Bavaria, some entries refer to unincorporated areas. The official announcement by the respective federal state is binding; links to these announcements are provided under each federal state.

Baden-Württemberg · Bavaria · Lower Saxony · Saxony · Saxony-Anhalt · Thuringia

Baden-Württemberg · 29 entries

State Announcement →
CountyMunicipalities
Breisgau-High Black ForestBollschweil, Horben, Münstertal, Oberried, Schluchsee
LörrachAitern, Böllen, Fröhnd, Häg-Ehrsberg, Kleines Wiesental, Schönau im Schwarzwald, Schönenberg, Todtnau, Tunau, Utzenfeld, Wembach, Wieden, Zell im Wiesental
Ortenau DistrictGutach (Black Forest Railway)
RottweilLauterbach, Schiltach
Schwarzwald-Baar DistrictSchonach
WaldshutDachsberg, Häusern, Herrischried, Ibach, Rickenbach, Sankt Blasien, Todtmoos

Bavaria · 26 entries

State Announcement →
CountyMunicipalities
Wunsiedel in the FichtelgebirgeArzberg, Bad Alexandersbad, Höchstädt in the Fichtelgebirge, Hohenberg on the Eger, Kaiserhammer Forest-East, Kirchenlamitz, Marktleuthen, Marktredwitz, Martinlamitzer Forest-South, Meierhöfer Side, Nagel, Neubauer Forest-South, Röslau, Schirnding, Schönwald, Selb, Thiersheim, Thierstein, Tröstau, Tröstauer Forest-East, Tröstauer Forest-West, Vordorfer Forest, Weißenstadt, Weißenstadt Forest-North, Weißenstadt Forest-South, Wunsiedel

Lower Saxony · 3 entries

State Announcement →
CountyMunicipalities
GoslarGoslar, Clausthal-Zellerfeld, Braunlage

Saxony · 107 entries

State Announcement →
CountyMunicipalities
Erzgebirge DistrictAmtsberg, Annaberg-Buchholz, Aue-Bad Schlema, Auerbach, Bärenstein, Bockau, Börnichen/Erzgeb., Breitenbrunn/Erzgeb., Burkhardtsdorf, Crottendorf, Deutschneudorf, Drebach, Ehrenfriedersdorf, Eibenstock, Elterlein, Gelenau/Erzgeb., Geyer, Gornau/Erzgeb., Großolbersdorf, Großrückerswalde, Grünhain-Beierfeld, Grünhainichen, Heidersdorf, Johanngeorgenstadt, Jöhstadt, Königswalde, Lauter-Bernsbach, Marienberg, Mildenau, Oberwiesenthal, Olbernhau, Pockau-Lengefeld, Raschau-Markersbach, Scheibenberg, Schlettau, Schneeberg, Schönheide, Schwarzenberg/Erzgeb., Sehmatal, Seiffen/Erzgeb., Stollberg/Erzgeb., Stützengrün, Tannenberg, Thalheim/Erzgeb., Thermalbad Wiesenbad, Thum, Wolkenstein, Zschopau, Zschorlau
Central SaxonyAugustusburg, Bobritzsch-Hilbersdorf, Brand-Erbisdorf, Dorfchemnitz, Eppendorf, Flöha, Frauenstein, Freiberg, Großhartmannsdorf, Halsbrücke, Leubsdorf, Lichtenberg/Erzgeb., Mulda/Sa., Neuhausen/Erzgeb., Oberschöna, Oederan, Rechenberg-Bienenmühle, Sayda, Weißenborn/Erzgeb.
Saxon Switzerland–Eastern Ore MountainsAltenberg, Bad Gottleuba-Berggießhübel, Dippoldiswalde, Dorfhain, Freital, Glashütte, Hartmannsdorf-Reichenau, Hermsdorf (Erzgebirge), Klingenberg, Kreischa, Liebstadt, Tharandt
Vogtland DistrictAdorf/Vogtl., Auerbach/Vogtl., Bad Brambach, Bad Elster, Bergen, Eichigt, Ellefeld, Falkenstein/Vogtl., Grünbach, Klingenthal, Lengenfeld, Markneukirchen, Mühlental, Muldenhammer, Neustadt/Vogtl., Rodewisch, Schöneck/Vogtl., Steinberg, Theuma, Treuen, Werda
ZwickauCrinitzberg, Hartmannsdorf near Kirchberg, Hirschfeld, Kirchberg, Langenweißbach, Wilkau-Haßlau

Saxony-Anhalt · 15 entries

State Announcement →
CountyMunicipalities
HarzFalkenstein/Harz, Harzgerode, Ilsenburg (Harz), Oberharz am Brocken, Thale, Wernigerode
Mansfeld-SüdharzAllstedt, Arnstein, Hettstedt, Lutherstadt Eisleben, Mansfeld, Sangerhausen, Südharz, Goldene Aue, Mansfelder Grund-Helbra

Thuringia · 19 entries

State Announcement →
CountyMunicipalities
Altenburg RegionPosterstein
GothaLuisenthal, Tambach-Dietharz/Thuringian Forest
GreizKauern, Korbußen, Paitzdorf, Ronneburg
HildburghausenMasserberg, Schleusegrund
Ilm DistrictElgersburg, Großbreitenbach, Ilmenau
Saalfeld-RudolstadtGräfenthal, Katzhütte, Schwarzatal
Schmalkalden-MeiningenFloh-Seligenthal, Oberhof
SonnebergGoldisthal
Wartburg DistrictRuhla
Excluding radon-risk areas. The remaining ten states have not designated any such areas: Berlin, Brandenburg, Bremen, Hamburg, Hesse, Mecklenburg-Western Pomerania, North Rhine-Westphalia, Rhineland-Palatinate, Saarland, and Schleswig-Holstein. The mandatory testing requirement also applies there for the aforementioned work areas, and elevated levels are possible in individual buildings.

When Continuous Monitoring Helps

Between Mandatory Measurements

The legally required measurement provides an annual average after twelve months. It does not reveal whether ventilation or sealing is effective until the next mandatory measurement—up to 30 months later.

For the mandatory measurement, only devices from a BfS-approved agency are accepted, including both passive detectors and electronic measuring devices. A separate continuous monitoring system does not replace these mandatory measurements, but it does show in real time when levels are rising and whether a measure is effective, and can control ventilation via the building automation system. The EnoSense® RADON transmits a measurement value via radio every 10 minutes for this purpose.

Continuous Monitoring in the Field

From the Field · European Radon Day 2026

The University of La Laguna on Tenerife demonstrates how continuous monitoring can help in decision-making. It presented its findings at the 2026 EnOcean Alliance Summit; here are the key takeaways in 45 seconds:

  • Radon levels can fluctuate by up to a factor of 10 in a single day. A single measurement per room does not indicate when exposure levels are high.
  • On the Anchieta Campus, 1 out of 5 rooms exceeds the EU reference value of 300 Bq/m³.
  • Side by side with a calibrated reference: correlation r = 0.96.
  • In the lecture hall: With positive-pressure supply air running at just 30% capacity, the level drops from 1,044 to 70 Bq/m³ during lectures.

The official assessment relies on the passive detector. The sensor network indicates where and when action is needed.

Animation without sound, 45 seconds · Source: Universidad de La Laguna

Frequently Asked Questions

5 Questions

How can I find out if a location is in a radon-prone area?

Search for the municipality in the list on this page or on the map provided by the Federal Office for Radiation Protection. The state’s official announcement is binding; if in doubt, contact the state authority for information.

Do you have to measure radon levels outside a radon precautionary area?

Only at workplaces in certain sectors, such as water treatment plants, mines, or radon spas, or if the authority requires it. However, elevated levels can also occur outside these areas; a voluntary measurement provides clarity.

Does the testing requirement also apply to offices on upper floors?

In radon-risk areas, the requirement applies to workplaces on the ground floor and in basements. For upper floors, it applies only if the work area falls under this requirement or if the authorities mandate it.

What happens if the reference value is exceeded?

Measures to reduce radon levels must be taken immediately, and their effectiveness must be verified by a measurement within 30 months. If the level remains above the threshold, the workplace must be reported to the authorities and the exposure assessed.

When are radon prevention zones reviewed?

The Radiation Protection Act requires a review at least every ten years. Most of these provisions have been in effect since late 2020 or mid-2021.

Newsletter

New planning aids by email

New devices, firmware and software releases, application examples and planning aids – roughly every two months, at most once a month.

Subscribe to the newsletter

Information current as of October 3, 2026. Sources: Radiation Protection Act, Sections 121 through 131 and Annex 8; Radiation Protection Ordinance, Sections 153 through 155; Federal Office for Radiation Protection, Overview of Radon Precautionary Areas (as of June 15, 2021); announcements by the federal states. This information has been compiled to the best of our knowledge and does not constitute legal advice; the text of the current version and the announcements by the federal states are authoritative.

Are you conducting measurements in a radon-prone area?

Please provide us with the location, the rooms in question, and the target system. You’ll receive a recommendation for continuous monitoring, a list of order numbers, and a quote.